The output of a tensile test is a graph giving the load versus the resulting extension of the test piece. These curves are dependent on the test piece size. If the test piece is larger it will require a larger load to give the same extension.
Therefore, in order to normalise across a range of different size test pieces, the load and extension are converted to engineering stress and engineering strain respectively (we will simply refer to these as stress and strain).
σÌý= stress
FÌý= force applied (load)
AÌý= cross-sectional area
εÌý= strain
δ±ôÌý= change in length
±ôÌý= original length
Ìý
Stress and strain are then plotted instead of load and extension, giving an engineering stress-strain curve, which is not dependent on the area or size of the test piece.
These curves can then be compared between different test pieces and different materials.